Latest Release: EasyMatch QC 4.99.13 (September 2024)
Please contact support@hunterlab.com to obtain the revision history for EZMQC.
System Compatibility:
EasyMatch QC 4.97 and above is compatible with the following Microsoft Windows operating systems: Windows 7 (32-bit and 64-bit), Windows 8, 8.1, Windows 10 and Windows 11.
For full compatibility details, please refer to the article on Windows operating systems for all EasyMatch QC and EasyMatch QC-ER software.
Upgrade Instructions:
-
Upgrading from EasyMatch QC 4.96 and above: When upgrading from previous versions of EasyMatch QC to 4.96 or higher, you must remove the old
sensors.dat
file located atC:\HunterLab\EasyMatchQC\Sensors
before opening the new EasyMatch QC. This is required to create additional tables for each sensor. -
Upgrading from EasyMatch QC 4.86 or below to the latest version: Perform a clean uninstall and reinstall the new EasyMatch QC version. Follow the steps below to do a clean uninstall and install:
Clean Uninstall and Reinstall Procedure:
- Log into the PC with an admin account.
- Close EasyMatch QC.
- Uninstall EasyMatch QC through the Control Panel.
- Restart the PC.
-
Stop Services (if still running):
- Go to Windows Services.
- Stop the following services (if running):
- HLsksvc
- HunterLab’s EPM Config Service
- Delete the following folders if they still exist:
-
C:\Program Files (x86)\HunterLab
(For 32-bit systems:C:\Program Files\HunterLab
) -
C:\Program Files (x86)\Common Files\HunterLab
(For 32-bit systems:C:\Program Files\Common Files\HunterLab
)
-
- Rename the
C:\HunterLab\EasyMatchQC
folder. (After installing the new version, you can copy all job files from the old folder to the new one.) - Install the newer EasyMatch QC version.
Multi-PC Recommendation:
If you are using multiple PCs with EasyMatch QC/QC-ER, it is recommended to install the latest version of EasyMatch QC/QC-ER on all PCs. Older versions of EasyMatch QC may not be able to open jobs created or modified by newer versions of EasyMatch QC/QC-ER. However, newer versions of EasyMatch QC/QC-ER are fully backward-compatible and can open jobs created or modified by older versions.
Important Note for Upgrades (without Clean Uninstall):
If you do not need to perform a clean uninstall, ensure that you remove or rename the sensors.dat
file created by previous versions of EZMQC before opening the newer version of EasyMatch QC. This file is located at C:\HunterLab\EasyMatchQC\Sensors
.