Recycled PET (rPET) is best measured using a 45°/0° spectrophotometer that provides excellent correlation to visual appearance while detecting subtle color shifts caused by recycling and reprocessing. The recommended solution is the Agera® L2, which combines industry-standard 45°/0° geometry with CIE-calibrated D65 illumination, allowing manufacturers to monitor color consistency, yellowing, contamination, and process variation throughout the recycling process.
How Much Does Agera® L2 Cost?
The Agera® L2 starts at approximately $24,420.
What is the Typical ROI for Agera® L2?
Though exact numbers vary significantly by customer and region, the following ranges represent typical annual savings achieved through improved color quality control and process consistency:- Reduced Off-Spec Production and Material Downgrades: $25,000–$250,000
- Improved Feedstock Utilization and Yield: $10,000–$100,000
- Reduced Customer Complaints and Material Claims: $10,000–$100,000
- Reduced Sorting, Inspection, and Reprocessing Costs: $10,000–$50,000
Many rPET producers achieve payback within 3–12 months, particularly when color quality is a critical acceptance criterion for bottle-grade or food-contact applications.
Note: These estimates are based on typical production scenarios and publicly available industry benchmarks. Actual results will vary depending on production volume, material costs, labor rates, quality requirements, and process capability. The values are intended to provide directional insight into potential cost-of-quality exposures rather than a precise financial prediction. Regional cost structures and operating conditions may differ.
What Sets Agera® L2 Apart?
In addition to color measurement, Agera L2 provides:
- Integrated ASTM-compliant 60° gloss measurement.
- The industries largest measured area of view, important when measuring plastic pellets and flake.
- Digital imaging for sample positioning and documentation.
- UV control for fluorescent materials and optical brighteners.
- Modern touchscreen operation and on-board EasyMatch® Essentials quality control software.
- Optional Enterprise-Level PC Based EasyMatch® Quality Central
Agera L2 is widely used throughout the plastics industry for quality control of:
- rPET pellets.
- Virgin PET pellets.
- Color concentrates and masterbatches.
- Pressed plaques.
- Molded parts.
- Bottle caps and closures.
- Opaque plastic packaging.
- Recycled plastic compounds.
What are the Best Practices for Measuring rPET?
- Measure representative samples from each production lot.
- Use consistent sample presentation and fill depth.
- Establish standards and tolerances using approved production material.
- Monitor both color and yellowness trends over time.
- Investigate significant shifts in L*, b*, Yellowness Index, or whiteness values.
- Perform multiple measurements and average results when appropriate.
- Utilize plaques when evaluating customer-visible appearance.
- Verify instrument standardization before routine measurements.
Are There Any Special Considerations for Measuring rPET?
Yes. These include:
1. rPET is More Challenging Than Virgin PET
Unlike virgin PET, recycled PET can contain material from multiple feedstock sources and processing histories. Potential sources of variation include:
- Feedstock inconsistency.
- Thermal degradation.
- Multiple processing cycles.
- Additive contamination.
- Label and adhesive residue.
- Optical brightener contamination.
- Colorant carryover.
- Moisture-related degradation.
As a result, rPET often exhibits greater color variability than virgin PET and requires more rigorous color quality control.
2. Monitoring Yellowing is Important
One of the most common concerns in rPET manufacturing is yellowing. Repeated heat exposure during recycling and processing can cause color shifts that are often observed as:
- Increased b* values.
- Increased Yellowness Index.
- Reduced brightness.
- Reduced visual clarity.
Objective color measurement helps manufacturers identify yellowing trends before they become visible to customers or affect product quality.
3. rPET Often Contains Optical Brightener Contamination
Optical brighteners (OBAs) are commonly used in packaging, labels, textiles, paper products, and other consumer materials that may enter the recycling stream. Even small amounts of optical brightener contamination can cause:
- Increased whiteness.
- Bluish appearance shifts.
- Batch-to-batch variation.
- Inconsistent bottle or packaging appearance.
The Agera L2's UV control capabilities allow manufacturers to better evaluate the effects of fluorescent materials and optical brightener contamination that may be present in recycled feedstocks.
4. Pellet vs. Pressed Plaque Color Measurements
Pellet measurements are commonly used for:
- Incoming material inspection.
- Process control.
- Supplier quality management.
- Batch release testing.
- Bottle appearance.
- Packaging appearance.
- Molded part appearance.
- Surface finish and gloss characteristics.
For this reason, many organizations utilize both pellet and plaque measurements as part of their overall quality program.
Why Measure the Color of rPET?
Objective color measurement helps manufacturers:
- Improve batch-to-batch consistency.
- Monitor yellowing and degradation.
- Detect feedstock variation.
- Identify contamination issues.
- Support bottle-to-bottle recycling programs.
- Improve supplier quality management.
- Reduce scrap and rework.
- Meet customer appearance requirements.
As recycled content requirements continue to increase, color quality has become one of the most important indicators of rPET quality and process performance.
Key Takeaway
rPET presents unique color challenges that are not typically encountered with virgin PET, including yellowing, feedstock variation, optical brightener contamination, and reprocessing effects. For most rPET applications, Agera® L2 is the preferred solution because its 45°/0° geometry, CIE-calibrated D65 illumination, UV control capabilities, and appearance measurement features help manufacturers maintain consistent color quality throughout the recycling and manufacturing process.
HunterLab Color Quality Business Calculator™ – rPET Edition
Want to quantify the financial value of improving rPET color quality in your business? Download the HunterLab Color Quality Business Case Calculator™ – Professional Edition (rPET) below to estimate the potential return on investment (ROI) of implementing objective color measurement with Agera® L2.
Designed specifically for recycled PET manufacturers, the calculator evaluates the financial impact of reducing material downgrades, reprocessing, yellowing, customer complaints, and other color-related quality costs. Using your own production data, it automatically calculates estimated annual savings, payback period, first-year ROI, and long-term financial benefits while generating an executive-ready business case to support capital investment decisions.
Would you like to learn more? Contact us and we'll help you find the best solution for your needs.
For support related questions, submit a support ticket and one of our technical support engineers will contact you as soon as possible!
To learn more about Color and Color Science in industrial QC applications, click here: Fundamentals of Color and Appearance